Innovative Application of Scanning, Printing and Pressure Sensors Technologies to Improve Patient Experience in Auricular Keloids Management

Innovative Application of Scanning, Printing and Pressure Sensors Technologies to Improve Patient Experience in Auricular Keloids Management

 

Ka-Wing Wong, Ching-Sheung Chan, Wai-Kin Ching

Deparment of Occupationad Therapy. Norh District Hospital, Hospital A whority, HIKSAR

BACKGROUND

Auricular keloids pose significant clinical challenges due to their high recurrence rates, cosmetic impact, and potential discomfort for patients. Compression or pressure therapy by splinting as adjunct treatment has been reported to be effective. An innovative application of 3D scanning and printing technology as well as pressure sensors to increase the precision of splint fitting, thereby shortening the therapist-patient contact time and reducing the frequency of clinic visits. The aim of this study is to explore the feasibility of technology applications to improve the efficiency and comfort level for patients in auricular keloid management.

M E T H O D S A case study methodology was used. Following the occupational therapist's keloid assessment during the first therapy session, the auricular keloids were scanned using a portable 3D scanning technology. An individual ear model was made by 3D printing for testing and fitting of the compression splint without the presence of the patient.

Pressure sensors were applied to measure the optimal pressure provided by the compression adjustable splint. On the second session, the therapist might use the ear model to empower the patient and teach them how to fit the splint. Minor adjustments would be made if necessary to increase the level of comfort of the compression splint.

Patients' conditions were followed up by mixed tele-mode and physical-mode follow-ups according to the patient's level of competency in self-management and the needs of the compression splint renewal. Users' satisfaction survey, adherence to compression splints, keloid conditions, and logic model framework analysis would be used to evaluate the inputs, outputs, and outcomes of this innovation.

RESULTS Three patients with auricular keloids with sizes ranging from 1 to 2 cm completed the 6-month therapy. Keloid volume, measured via comparative 3D imaging, was reduced by an average of 34%. Vancouver Scar Scale scores improved from a mean of 8.7 at baseline to 6.7 at 6 months, reflecting positive changes in vascularity, pliability, and height.

The self-administering survey reported an average daily splint-wearing time of 17 hours, demonstrating strong adherence to therapy. All 3 patients reported the therapy arrangement, including the duration of assessment, scanning, fitting, and frequency of follow-ups, was highly satisfactory.

C O N C L U S I O N

The integrative application of low-cost, market-available technologies in scanning, ear model printing, and pressure sensors to auricular keloid management is promising to improve the efficacy and adherence to the compression therapy by reducing therapist-patient contact time and enhancing patient comfort.

Contact Information
DetailFirst Author (Presenting)Co-Author
Full NameKa-Wing WONGChing-Sheung CHAN
Academic Degree(s)MSc in Stroke and Clinical NeurosciencesMSc in Musculoskeletal Medicine and Rehabilitation
InstitutionNorth District Hospital, Hospital Authority, Hong KongNorth District Hospital, Hospital Authority, Hong Kong
AddressOccupational Therapy Department, 1/F, North District Hospital, Sheung Shui, Hong Kong SAROccupational Therapy Department, 1/F, North District Hospital, Sheung Shui, Hong Kong SAR
Email Addresswkw160@ha.org.hkccs721@ha.org.hk
DisclosureNo conflict of interestNo conflict of interest